NITAL Testing
As part of our inspection of manufactured parts, MTA Industrie offers Nital Attack testing on all ground parts in addition to dimensional checks.
NITAL testing apparatus - MTA Industrie The operating method used has been developed in accordance with ISO standard 14104:1995. The main phases to consider during the operating procedure are :
Chemical attacking with acid, called Nital Testing, is an inspection method for detecting local overheating defects on ground surfaces. It applies to steels such as those used for gear teeth, shafts, splines, etc., and shows up areas that have been greatly overheated to the point of being rehardened (traces of wwhite) or areas overheated to the point of being retempered (traces of dark grey or black).
MTA Industrie carries out Nital attacking using personnel trained in this method:

All MTA Industrie services:
General Mechanical engineering
Gear cutting
Tooth and cylindrical grinding
Inspection
Special processes